Shopping Cart
No items in shopping cart
Continue shoppingNo items in shopping cart
Continue shopping
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G110 - CPM110 AC-DRIVE, WITH INTEGR. FILTER B 1AC200-240V + 10 / -10% 47-63HZ ANALOG INPUT CT: 0.12KW; VT: 0.12KW CT OVERLOAD: 150% 60S 150 X 90 X 116 (HXBXT) PROTECTION IP20 AMBIENT TEMPERATURE -10 + 50GRD C WITHOUT BOP WITHOUT RS485 INTERFACE

SINAMICS G110 - CPM110 AC-DRIVE, WITH INTEGR. FILTER B 1AC200-240V + 10 / -10% 47-63HZ ANALOG INPUT CT: 0.12KW; VT: 0.12KW CT OVERLOAD: 150% 60S 150 X 90 X 116 (HXBXT) PROTECTION IP20 AMBIENT TEMPERATURE -10 + 50GRD C WITHOUT BOP WITHOUT RS485 INTERFACE
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G110-CPM110 AC DRIVE, WITH INTEGR. FILTER B 200-240V1AC+10/-10% 47-63HZ ANALOG INPUT CT: 0.12 KW; VT: 0.12 KW CT OVERLOAD: 150% 60S 150X 90X 116 (HXWXD) DEGREE OF PROTECTION IP20 AMBIENT TEMPERATURE -10+50 °C WITHOUT BOP WITHOUT RS485 INTERFACE

SINAMICS G110-CPM110 AC DRIVE, WITH INTEGR. FILTER B 200-240V1AC+10/-10% 47-63HZ ANALOG INPUT CT: 0.12 KW; VT: 0.12 KW CT OVERLOAD: 150% 60S 150X 90X 116 (HXWXD) DEGREE OF PROTECTION IP20 AMBIENT TEMPERATURE -10+50 °C WITHOUT BOP WITHOUT RS485 INTERFACE
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G110-CPM110 AC DRIVE, UNFILTERED 200-240V1AC+10/-10% 47-63HZ ANALOG INPUT CT: 0.12 KW; VT: 0.12 KW CT OVERLOAD: 150% 60S 150X 90X 116 (HXWXD) DEGREE OF PROTECTION IP20 AMBIENT TEMPERATURE -10+50 °C WITHOUT BOP WITHOUT RS485 INTERFACE

SINAMICS G110-CPM110 AC DRIVE, UNFILTERED 200-240V1AC+10/-10% 47-63HZ ANALOG INPUT CT: 0.12 KW; VT: 0.12 KW CT OVERLOAD: 150% 60S 150X 90X 116 (HXWXD) DEGREE OF PROTECTION IP20 AMBIENT TEMPERATURE -10+50 °C WITHOUT BOP WITHOUT RS485 INTERFACE
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.25KW; VT: 0.25KW CT-OVERLOAD: 150% 60S 150 X 90 X 116 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE

SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.25KW; VT: 0.25KW CT-OVERLOAD: 150% 60S 150 X 90 X 116 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G110 - CPM110 AC-DRIVE, W/O FILT.,LOW LEAKAGE 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.37KW; VT: 0.37KW CT-OVERLOAD: 150% 60S 150 X 90 X 116 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE

SINAMICS G110 - CPM110 AC-DRIVE, W/O FILT.,LOW LEAKAGE 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.37KW; VT: 0.37KW CT-OVERLOAD: 150% 60S 150 X 90 X 116 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G110-CPM110 AC DRIVE, UNFILTERED 200-240V1AC+10/-10% 47-63HZ RS485 INTERFACE (USS PROTOCOL) CT: 0.37KW; VT: 0.37KW CT OVERLOAD: 150% 60S 150X 90X 116 (HXWXD) DEGREE OF PROTECTION IP20 AMBIENT TEMPERATURE -10+50 °C WITHOUT BOP WITHOUT ANALOG INPUT

SINAMICS G110-CPM110 AC DRIVE, UNFILTERED 200-240V1AC+10/-10% 47-63HZ RS485 INTERFACE (USS PROTOCOL) CT: 0.37KW; VT: 0.37KW CT OVERLOAD: 150% 60S 150X 90X 116 (HXWXD) DEGREE OF PROTECTION IP20 AMBIENT TEMPERATURE -10+50 °C WITHOUT BOP WITHOUT ANALOG INPUT
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G110-CPM110 AC DRIVE, UNFILTERED 200-240V1AC+10/-10% 47-63HZ ANALOG INPUT CT: 0.55KW; VT: 0.55KW CT OVERLOAD: 150% 60S 150X 90X 131 (HXWXD) DEGREE OF PROTECTION IP20 AMBIENT TEMPERATURE -10+50 °C WITHOUT BOP WITHOUT RS485 INTERFACE

SINAMICS G110-CPM110 AC DRIVE, UNFILTERED 200-240V1AC+10/-10% 47-63HZ ANALOG INPUT CT: 0.55KW; VT: 0.55KW CT OVERLOAD: 150% 60S 150X 90X 131 (HXWXD) DEGREE OF PROTECTION IP20 AMBIENT TEMPERATURE -10+50 °C WITHOUT BOP WITHOUT RS485 INTERFACE
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G110-CPM110 AC DRIVE, UNFILTERED 200-240V1AC+10/-10% 47-63HZ ANALOG INPUT CT: 0.75KW; VT: 0.75KW CT OVERLOAD: 150% 60S 150X 90X 131 (HXWXD) DEGREE OF PROTECTION IP20 AMBIENT TEMPERATURE -10+40 °C WITHOUT BOP WITHOUT RS485 INTERFACE

SINAMICS G110-CPM110 AC DRIVE, UNFILTERED 200-240V1AC+10/-10% 47-63HZ ANALOG INPUT CT: 0.75KW; VT: 0.75KW CT OVERLOAD: 150% 60S 150X 90X 131 (HXWXD) DEGREE OF PROTECTION IP20 AMBIENT TEMPERATURE -10+40 °C WITHOUT BOP WITHOUT RS485 INTERFACE
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G110-CPM110 AC DRIVE, UNFILTERED 200-240V1AC+10/-10% 47-63HZ RS485 INTERFACE (USS PROTOCOL) CT: 1.5KW; VT: 1.5KW CT OVERLOAD: 150% 60S 160X 140X 142 (HXWXD) DEGREE OF PROTECTION IP20 AMBIENT TEMPERATURE -10+40 °C WITHOUT BOP WITHOUT ANALOG INPUT

SINAMICS G110-CPM110 AC DRIVE, UNFILTERED 200-240V1AC+10/-10% 47-63HZ RS485 INTERFACE (USS PROTOCOL) CT: 1.5KW; VT: 1.5KW CT OVERLOAD: 150% 60S 160X 140X 142 (HXWXD) DEGREE OF PROTECTION IP20 AMBIENT TEMPERATURE -10+40 °C WITHOUT BOP WITHOUT ANALOG INPUT
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G110-CPM110 AC DRIVE, WITH INTEGR. FILTER A 200-240V1AC+10/-10% 47-63HZ RS485 INTERFACE (USS PROTOCOL) CT: 3.0KW; VT: 3.0KW CT OVERLOAD: 150% 60S 181X 184X 152 (HXWXD) DEGREE OF PROTECTION IP20 AMBIENT TEMPERATURE -10+40 °C WITHOUT BOP WITHOUT AN

SINAMICS G110-CPM110 AC DRIVE, WITH INTEGR. FILTER A 200-240V1AC+10/-10% 47-63HZ RS485 INTERFACE (USS PROTOCOL) CT: 3.0KW; VT: 3.0KW CT OVERLOAD: 150% 60S 181X 184X 152 (HXWXD) DEGREE OF PROTECTION IP20 AMBIENT TEMPERATURE -10+40 °C WITHOUT BOP WITHOUT AN
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G110-CPM110 AC DRIVE, UNFILTERED 200-240V1AC+10/-10% 47-63HZ RS485 INTERFACE (USS PROTOCOL) CT: 3.0KW; VT: 3.0KW CT OVERLOAD: 150% 60S 181X 184X 152 (HXWXD) DEGREE OF PROTECTION IP20 AMBIENT TEMPERATURE -10+40 °C WITHOUT BOP WITHOUT ANALOG INPUT

SINAMICS G110-CPM110 AC DRIVE, UNFILTERED 200-240V1AC+10/-10% 47-63HZ RS485 INTERFACE (USS PROTOCOL) CT: 3.0KW; VT: 3.0KW CT OVERLOAD: 150% 60S 181X 184X 152 (HXWXD) DEGREE OF PROTECTION IP20 AMBIENT TEMPERATURE -10+40 °C WITHOUT BOP WITHOUT ANALOG INPUT
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G110-CPM110 AC DRIVE, UNFILTERED 200-240V1AC+10/-10% 47-63HZ ANALOG INPUT CT: 0.12 KW; VT: 0.12 KW CT OVERLOAD: 150% 60S 150X 90X 101 (HXWXD) IP20; WITH FLAT HEAT SINK; ONLY FOR COOLING PLATE INSTALLATION AMBIENT TEMPERATURE -10+50 °C WITHOUT BOP

SINAMICS G110-CPM110 AC DRIVE, UNFILTERED 200-240V1AC+10/-10% 47-63HZ ANALOG INPUT CT: 0.12 KW; VT: 0.12 KW CT OVERLOAD: 150% 60S 150X 90X 101 (HXWXD) IP20; WITH FLAT HEAT SINK; ONLY FOR COOLING PLATE INSTALLATION AMBIENT TEMPERATURE -10+50 °C WITHOUT BOP
In partner stock - ships in 3-5 days