Shopping Cart
No items in shopping cart
Continue shoppingNo items in shopping cart
Continue shopping
In partner stock - ships in 3-5 days
SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 1,1KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C 173 X 73 X 145 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP

SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 1,1KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C 173 X 73 X 145 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 4,0KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C 270 X 153 X 165 (HXWXD), FSB PROTECTION IP20 WIT

SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 4,0KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C 270 X 153 X 165 (HXWXD), FSB PROTECTION IP20 WIT
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 11KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 15KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 334 X 189 X 185 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP

SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 11KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 15KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 334 X 189 X 185 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 15KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 18,5KW FOR 150% 3S,110% 57S,100% 240S

SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 15KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 18,5KW FOR 150% 3S,110% 57S,100% 240S
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 22KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 30KW FOR 150% 3S,110% 57S,100% 240S AM

SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 22KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 30KW FOR 150% 3S,110% 57S,100% 240S AM
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 30KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 37KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 635 X 275 X 204 (HXWXD), FSE PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP

SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 30KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 37KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 635 X 275 X 204 (HXWXD), FSE PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 45KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 55KW FOR 150% 3S,110% 57S,100% 240S AM

SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 45KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 55KW FOR 150% 3S,110% 57S,100% 240S AM
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 5,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 7,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 334 X 189 X 185 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP

SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 5,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 7,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 334 X 189 X 185 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 POWER MODULE PM 250 WITH INTEGRATED CLASS A FILTER CAPABLE OF ENERGY RECOVERY. 380-480 V 3 AC +10/-10% 47-63 HZ POWER HIGH OVERLOAD: 7.5KW AT 200% 3S, 150% 57S, 100% 240 S; AMBIENT TEMPERATURE 0 TO +50 °C POWER LOW OVERLOAD: 11KW AT 150% 3S,

SINAMICS G120 POWER MODULE PM 250 WITH INTEGRATED CLASS A FILTER CAPABLE OF ENERGY RECOVERY. 380-480 V 3 AC +10/-10% 47-63 HZ POWER HIGH OVERLOAD: 7.5KW AT 200% 3S, 150% 57S, 100% 240 S; AMBIENT TEMPERATURE 0 TO +50 °C POWER LOW OVERLOAD: 11KW AT 150% 3S,
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 POWER MODULE PM250 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 15KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 18,5KW FOR 150% 3S,110% 57S,100% 240S AMB

SINAMICS G120 POWER MODULE PM250 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 15KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 18,5KW FOR 150% 3S,110% 57S,100% 240S AMB
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 22KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 30KW FOR 150% 3S,110% 57S,100

SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 22KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 30KW FOR 150% 3S,110% 57S,100
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 37KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 45KW FOR 150% 3S,110% 57S,100

SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 37KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 45KW FOR 150% 3S,110% 57S,100
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
ASM_CONTROL 6SL3243-0BB30-1PA2-CU230P-2_DP_INT_PROFIBUS_DP_6DI_3DO_4AI_2AO_1_MOTORTEMP.-SENSOR-INP_2_PSU-OUT(10VDC_24VDC)_1PSU-IN_(2 4VDC)_USB-_UND_MMC-INTERFACE_IP20 INTEGRATED PROFIBUS DP 6 DI, 3 DO, 4 AI, 2 AO 1 MOTOR TEMP. SENSOR INPUT 2 PSU-OUT(10V DC, 24V DC) 1 PSU-IN (24V DC) USB- AND MMC-INTERFACE PROTECTION IP20

ASM_CONTROL 6SL3243-0BB30-1PA2-CU230P-2_DP_INT_PROFIBUS_DP_6DI_3DO_4AI_2AO_1_MOTORTEMP.-SENSOR-INP_2_PSU-OUT(10VDC_24VDC)_1PSU-IN_(2 4VDC)_USB-_UND_MMC-INTERFACE_IP20 INTEGRATED PROFIBUS DP 6 DI, 3 DO, 4 AI, 2 AO 1 MOTOR TEMP. SENSOR INPUT 2 PSU-OUT(10V DC, 24V DC) 1 PSU-IN (24V DC) USB- AND MMC-INTERFACE PROTECTION IP20
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 CONTROL UNIT CU240S S-TYPE STANDARD RS485-INTERFACE, USS-PROTOCOL 9 DI, 3 DO, 2 AI, 2 AO PTC/KTY INTERFACE EM-BRAKE RELAY, MMC INTERFACE ENCODER INTERFACE PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT POWER MODULE AND BOP

SINAMICS G120 CONTROL UNIT CU240S S-TYPE STANDARD RS485-INTERFACE, USS-PROTOCOL 9 DI, 3 DO, 2 AI, 2 AO PTC/KTY INTERFACE EM-BRAKE RELAY, MMC INTERFACE ENCODER INTERFACE PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT POWER MODULE AND BOP
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 CONTROL UNIT CU240S PN-F S-TYPE SAFETY INTEGRATED PROFINET 8 DI, 3 DO, 2 AI, 2 AO PTC/KTY INTERFACE EM-BRAKE RELAY, MMC INTERFACE ENCODER INTERFACE PROTECTION IP20 AMBIENT TEMP 0 TO +40 DEG C WITHOUT POWER MODULE AND BOP

SINAMICS G120 CONTROL UNIT CU240S PN-F S-TYPE SAFETY INTEGRATED PROFINET 8 DI, 3 DO, 2 AI, 2 AO PTC/KTY INTERFACE EM-BRAKE RELAY, MMC INTERFACE ENCODER INTERFACE PROTECTION IP20 AMBIENT TEMP 0 TO +40 DEG C WITHOUT POWER MODULE AND BOP
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 CONTROL UNIT CU240E-2 PN-F E-TYPE SAFETY INTEGRATED STO, SS1, SLS, PROFINET 6DI, 3DO, 2AI, 2AO, MAX 3F-DI PTC/KTY INTERFACE USB- AND SD/MMC-INTERFACE PROTECTION IP20 AMBIENT TEMP 0 TO +50 DEG C WITHOUT POWER MODULE AND PANEL

SINAMICS G120 CONTROL UNIT CU240E-2 PN-F E-TYPE SAFETY INTEGRATED STO, SS1, SLS, PROFINET 6DI, 3DO, 2AI, 2AO, MAX 3F-DI PTC/KTY INTERFACE USB- AND SD/MMC-INTERFACE PROTECTION IP20 AMBIENT TEMP 0 TO +50 DEG C WITHOUT POWER MODULE AND PANEL
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
FREQUENCY CONVERTER FOR ET 200S CONTROL UNIT MODULE WIDTH 15 MM COMBINEABLE WITH CONVERTER POWER MODULE IPM25 CONTROL METHODS: U/F,FCC,SLVC, VC WITH ENCODER, TORQUE CONTROL INPUT MOTOR ENC.: HTL UNIPOLAR INPUT MOTOR TEMP.: PTC/KTY RS232: START-UP-TOOL STARTER

FREQUENCY CONVERTER FOR ET 200S CONTROL UNIT MODULE WIDTH 15 MM COMBINEABLE WITH CONVERTER POWER MODULE IPM25 CONTROL METHODS: U/F,FCC,SLVC, VC WITH ENCODER, TORQUE CONTROL INPUT MOTOR ENC.: HTL UNIPOLAR INPUT MOTOR TEMP.: PTC/KTY RS232: START-UP-TOOL STARTER
In partner stock - ships in 3-5 days